What ASTM E23 covers
- Notched-bar impact testing (Charpy and Izod) that measures the energy a notched specimen absorbs when broken at a set temperature.
- Defines specimen size, notch geometry, machine requirements and how to condition specimens to the test temperature.
- Results are usually reported as absorbed energy, and often also as lateral expansion and percent shear fracture.
- Sub-size specimens are allowed for thin material; the product spec says how to scale the acceptance values.
Practical tips
- The time from leaving the temperature bath to impact is limited; slow transfers are a common cause of bad low-temperature results.
- Check that the machine has a current indirect verification with reference specimens.
Where ASTM E23 is used
Industries
Steelmaking Pipe and tube manufacturing Manufacturing (general) Oil and gas Midstream (pipelines and storage)
Categories
Use it to
Run a lab test Certify mill product
Region
United States International
Related codes
- Similar ISO 148-1: Metallic materials — Charpy pendulum impact test — Part 1: Test method · Compare ASTM E23 vs ISO 148-1
- Cited by ASTM A333/A333M: Standard Specification for Seamless and Welded Steel Pipe for Low-Temperature Service and Other Applications with Required Notch Toughness
- Cited by ASTM A370: Standard Test Methods and Definitions for Mechanical Testing of Steel Products
Starter packs that include it
- Making or buying line pipe: Charpy impact test method for the toughness requirements.
- Running a steel mill or test lab: Charpy test method.