- Quality Engineering
- Intermediate
- 25 min
- 5 interactives
- CQE · CSSBB · CMBB
Top-Down vs. Bottom-Up Risk Assessment
Every risk tool digs in one of two directions. Top-down vs. bottom-up risk assessment comes down to one question: do you start from the bad outcome and dig for causes, or start from each part and ask what it could break?
“This bad thing happened, or could. What causes it?”
Think: the detectiveStart at the event. Dig back to causes, walk forward to effects.
Bow-tie · HAZOP“If this part fails, what does it break?”
Think: the inspectorPoster: top-down digs from the outcome down to causes, like a detective. Middle-out starts at the event and works both ways. Bottom-up walks from each part up to its effects, like an inspector.
Climb the system ladder both ways
Every product or process stacks up like a ladder: parts make steps, steps make a line, the line makes what the customer gets. Pick a direction, then press Next step and watch which rung you visit first.
- System / customerWaiting…
- Line / unitWaiting…
- Process stepWaiting…
- Part / failure modeWaiting…
Top-down chosen. Press Next step to start at the top.
Pipe-mill examples are made up for teaching.
Meet the 9 tools, sorted by direction
Colour tells you the direction. The chips tell you the timing: proactive (before a failure) or reactive (after one). Open any card for a steel-mill example.
Top-down
Outcome → causes · deductiveFault tree analysis (FTA)
One top event, traced down through AND / OR gates to basic causes.
- Proactive
- Reactive
“Pipe ruptures in service” as the top event, traced to wall loss, low toughness, or a seam defect that UT missed.
RCA: 5-Why · Fishbone
Start from the defect you saw. Ask why, or brainstorm the 6M bones, until you hit the root cause.
- Reactive
“Why did this heat fail its Charpy test?” Why? Grain too coarse. Why? Finish rolling ran hot. Why? …
Middle-out
Event → both waysBow-tie
The event sits in the knot. Causes and prevention barriers on the left, consequences and recovery barriers on the right.
- Proactive
Show the board every barrier between “pipe ruptures” and a spill: UT, hydrotest and Charpy on the left; leak detection and shutdown on the right.
HAZOP
Guide word + parameter = deviation (“no flow”). Work back to causes and forward to consequences, node by node.
- Proactive
Review the caster’s mould cooling-water loop on its P&ID before start-up. Try it yourself in Part 5.
Bottom-up
Cause → effects · inductiveFMEA / FMECA
Every failure mode of every step, rated for severity, occurrence and detection.
- Proactive
A PFMEA row for ERW seam welding: “cold weld” → leak in hydrotest or service.
HACCP
Step by step: list each hazard, then set critical control points and limits.
- Proactive
Built for food and drugs. In a mill, think of a food-grade coating line.
PHA
Preliminary Hazard Analysis: an early scan of hazards for each part of a new system.
- Proactive
A concept for a new pickling line, before the detailed design exists.
HAZID
Hazard identification: a broad first scan of a layout or concept, including how systems affect each other.
- Proactive
The site layout for a new acid regeneration plant: what if acid storage sits next to the crane bay?
What-If / SWIFT
Structured “What if…?” prompts at each step. Faster and lighter than FMEA.
- Proactive
“What if the crane drops a bundle at the loading bay?” Walk every step that way.
Side by side
Scroll sideways to see all columns.
| Aspect | Top-down | Bottom-up |
|---|---|---|
| Starts at | A defined bad outcome | A part, step or failure mode |
| Logic | Deductive: outcome → causes | Inductive: cause → effects |
| Blind spot | Causes nobody put in the tree | Combinations and interactions between parts |
| Best for | One known or feared failure | Full coverage before failures happen |
| Pairs with | RCA, CAPA, 8D | DFMEA, PFMEA action plans |
Why HAZOP is “middle-out”: textbooks file it as top-down and as bottom-up. It really starts at a deviation in the middle and works both ways, just like the bow-tie.
Proactive or reactive? Before or after the failure
A proactive tool finds risk before anything breaks. A reactive tool explains a failure that already happened, so you can fix it and stop it coming back.
Proactive
Before anything breaks
- FMEA
- HACCP
- PHA
- HAZID
- SWIFT
- HAZOP
- Bow-tie
- FTA at design
- HAZAN
Reactive
After it breaks
- 5-Why
- Fishbone
- FTA in an investigation
- CAPA / 8D
≠ timing
Exam trap: top-down does not mean reactive. FTA is top-down, yet engineers often build it at the design stage, long before anything fails. Ask two separate questions: which way? and before or after?
The sorting game: which way would you dig?
Eight real jobs from a pipe mill. Pick the direction for each one. You get one try per job.
1. Heat 4417 failed its Charpy test yesterday. Find out why.
2. A new ERW line starts in three months. List every way each step could fail.
3. Review the P&ID of the new caster cooling-water loop before start-up.
4. Show the board every barrier between a pipe rupture and an oil spill.
5. Before launch, prove how “pipe ruptures in service” could happen, with AND / OR logic.
6. Scan a concept for a new pickling line for hazards, before the design is detailed.
7. Walk the site layout for a new acid regeneration plant: what hazards exist at all?
8. Before start-up, put a number on how often a caster breakout could happen, and decide if that is tolerable.
Spin the HAZOP guide word machine
HAZOP uses seven guide words (guide, not “guild”). Each one, paired with a process parameter, names a deviation from design intent. The team then asks four questions about it.
Guide word+Parameter=Deviation
Node: caster mould cooling water. Pick a guide word and a parameter.
Guide word
Parameter
A made-up example for teaching. Your plant’s HAZOP team will find its own causes and safeguards.
The N/A cards are the point. Many combinations mean nothing. The team still says them out loud and rules them out. That discipline is what makes HAZOP more complete than a free brainstorm.
HAZOP fits continuous processes with flow, pressure, temperature, level or composition: caster cooling water, EAF off-gas, ladle argon stirring. For final pipe inspection, use a PFMEA.
Where HAZOP sits: HAZID → HAZOP → HAZAN
HAZOP is the middle of three studies. Trevor Kletz put it simply: HAZOP identifies hazards, HAZAN assesses them. HAZID comes first, while the plant is still a layout. Tap each stage.
HAZID: hazard identification
- AsksWhat hazards exist here at all?
- Looks atThe layout or concept, and how systems affect each other
- You finish withA hazard register
- Direction · timingBottom-up · proactive
- ISO 310001 · Identify
- Pipe-mill exampleAcid storage next to the crane bay on a new layout
Pipe-mill examples are made up for teaching.
Big hazard staring at you? Kletz notes that an obvious major hazard can go to HAZAN before the HAZOP is done. Don’t wait to size it.
Fault tree lab: why FMEA needs a partner
FMEA looks at one failure mode at a time. A fault tree’s AND gate catches what it misses: two things going wrong together. Move the sliders to see how each cause drives the top event.
What-if sliders
The gate maths, for independent events:
where \(P(\text{W})\), \(P(\text{T})\), \(P(\text{D})\) and \(P(\text{M})\) are the chances of each basic event per pipe, and \(P(\text{S})\) is the chance that a seam defect escapes.
The bottom-up partner: one PFMEA row
| Step | Failure mode | Effect | Cause · control |
|---|---|---|---|
| ERW seam welding | Cold weld (lack of fusion) | Leak or rupture in hydrotest or service | Low heat input · online UT of the seam |
PFMEA every step + FTA the big one
Run the PFMEA across the whole rolling and finishing line for coverage. Then build a fault tree for each catastrophic event, so combinations get caught too.
Putting numbers on one hazard like this is HAZAN (hazard analysis). The answer tells you how far to go in reducing the risk.
Where the tools plug into ISO 31000
ISO 31000:2018 is the international guideline for managing risk. Its process (clause 6) calls risk identification, analysis and evaluation together risk assessment. That is where every tool on this page lives.
Risk assessment = steps 1 to 3Scope
Context and risk criteria: how much risk is OK?
1 · Identify
What could go wrong?
- HAZID
- HAZOP
- SWIFT
- PHA
- FMEA modes
2 · Analyze
How, how likely, how bad?
- HAZAN
- FTA
- Bow-tie
- FMEA S·O·D
3 · Evaluate
Is it acceptable?
- HAZAN
- Risk matrix
- RPN / AP
4 · Treat
Act on the risk
- FMEA actions
- Barriers
- HACCP CCPs
↺ Monitoring & reviewRCA and CAPA after failures feed back into the assessment
Communication & consultation runs through every step: a HAZOP or FMEA is a team sport.
Recording & reporting: FMEA worksheets, HAZOP logs, the risk register.
Proactive tools feed steps 1 to 4. Reactive tools feed monitoring and review, which updates the assessment. ISO 31000’s companion, IEC 31010:2019, describes each technique in detail. ISO 31000:2018 is still current; a revision is in progress.
Five mistakes to avoid
Don’t be that team
- “Top-down = reactive”Direction is not timing. A design-stage FTA is proactive.
- Trusting FMEA aloneIt rates one failure mode at a time. Add FTA for combinations.
- HAZOP on an inspection benchHAZOP is for continuous flows. Use PFMEA for discrete steps.
- Skipping the N/A guide wordsRuling them out on record is what makes HAZOP complete.
- Stopping at “operator error”Keep asking why until you reach a cause you can fix.
Do it in software
Statistics Implementation
Psst. Excel can run your fault-tree gates and FMEA ratings in one line each, and the exam loves asking how.You found the secret level. Gate maths, RPN tricks and menu paths are all below.
Unlock the cheat codesHide the cheat codes
Excel functions
| Function | Syntax | Purpose | When to use it |
|---|---|---|---|
PRODUCT | =PRODUCT(B2:B3) | Multiplies the cells | AND gate: all inputs must happen (independent events) |
1-PRODUCT(1-…) | =1-PRODUCT(1-B2:B4) | Chance that at least one input happens | OR gate. Works directly in Excel 365; older Excel needs Ctrl+Shift+Enter |
PRODUCT (RPN) | =PRODUCT(D2:F2) | Severity × Occurrence × Detection | Classic FMEA risk priority number |
RANK.EQ | =RANK.EQ(G2,$G$2:$G$40) | Rank of one RPN in the list | Find the top risks to act on first |
SORTBY | =SORTBY(A2:G40,G2:G40,-1) | Sorts rows by RPN, highest first | A live “worst first” view (Excel 365) |
COUNTIFS | =COUNTIFS(D2:D40,">=9") | Counts rows meeting a rule | How many failure modes have severity 9 or 10? |
Excel use cases
- Fault tree: put W, T, D and M in B2:B5 as decimals.
=B4*B5gives S.=1-PRODUCT(1-B2:B3,1-B6)with S in B6 gives the top event. Try 0.0002, 0.0001, 0.005 and 0.05: the top event comes out near 0.00055, matching the lab. - FMEA: severity, occurrence and detection in D:F,
=PRODUCT(D2:F2)in G2, fill down, thenSORTBYto list the worst first. - Watch severity on its own: a severity of 10 needs action even when the RPN is low.
COUNTIFSflags those rows.
where \(S\) is severity, \(O\) is occurrence and \(D\) is detection, each rated 1 to 10.
Minitab navigation
- Compute RPN:
Calc → Calculator, store the result in a new column, expressionS * O * D. - Pareto of RPN by failure mode:
Stat → Quality Tools → Pareto Chart. Choose Chart defects table, labels = failure mode, frequencies = RPN. - Alternative:
Graph → Bar Chartwith values from a table, if you want the bars unsorted. - FMEA forms: Minitab Statistical Software has no FMEA or fault-tree menu. Minitab Workspace, a separate product, has FMEA, fishbone and Five Whys forms. Build gate maths in
Calc → Calculatoror Excel.
Exam tips
- Deductive = top-down = FTA. Inductive = bottom-up = FMEA. Event tree analysis is also inductive.
- AND gates multiply. Expect a question that asks for the top event from two or three basic-event probabilities.
- Bow-tie = a fault tree on the left plus an event tree on the right.
- HAZOP identifies, HAZAN assesses. HAZID comes first, at the concept or layout stage.
- HAZOP = guide words × parameters at each node of a P&ID.
- RPN ranks risks but hides severity. The AIAG-VDA FMEA handbook uses Action Priority (AP) instead.
Four wall posters to take with you
Same topic, four layouts. Pick the one that matches how you think. Each is a one-page PDF that prints at 18 × 24 in.
-
Quick Reference
Download PDF of the Quick Reference poster -
Sorting Map
Download PDF of the Sorting Map poster -
Which Risk Tool Do I Need?
Download PDF of the Which Risk Tool Do I Need? poster -
One Event, Two Directions
Download PDF of the One Event, Two Directions poster
Knowledge check
Check your understanding
Comprehension quiz
Pick the strongest answer, then submit. Explanations appear after you submit.
References
- ISO 31000:2018, Risk management: Guidelines. International Organization for Standardization.
- IEC 31010:2019, Risk management: Risk assessment techniques. IEC and ISO.
- IEC 61882:2016, Hazard and operability studies (HAZOP studies): Application guide.
- IEC 60812:2018, Failure modes and effects analysis (FMEA and FMECA).
- IEC 61025:2006, Fault tree analysis (FTA).
- Kletz, T. A. (1999). HAZOP and HAZAN: Identifying and Assessing Process Industry Hazards (4th ed.).
- AIAG and VDA, FMEA Handbook (2019).